Mode, Inddescr, List o – Siemens AC75 User Manual

Page 83: Ac75 at command set

Advertising
background image

AC75 AT Command Set

3.2 AT+CIND

s

AC75_ATC_V01.002

Page 83 of 569

10/30/06

Confidential / Released

String values and their

<indValue>

ranges.

More indications are available via

AT^SIND

. Therefore use of

AT^SIND

for control of all indications is recom-

mended.

The following indications are accessible via

AT+CIND

:

“battchg“

Battery charge level 0..4 or 5 if no measuring is performed, e.g because no bat-

tery is connected. Also refer to

AT^SBC

.

“signal“

Signal quality (0..7)

The indicated value is the bit error rate of the signal received. Bit errors are esti-

mated values. See also

AT+CSQ

.

“service“

Service availability (0-1)

0: Not registered to any network

1: Registered to home network or, if "roam"=1 then registered to another net-

work

“sounder“

Sounder activity (0-1)

Reports every event that causes the ME to generate a tone.

Value 1 means for example:

Incoming call - ME is ringing. Note that the URC "

+CIEV

: sounder" will be out-

put only if ringing tones are activated with

AT^SRTC

.

Waiting call - ME generates waiting call tone (if call waiting is enabled).

Outgoing call - ME generates Call Progress tone.

Outgoing call - ME generates BUSY tone.

The value changes to 0 when the tone stops.

“message“

Unread short message at memory location

<mem1>

(0-1); refer to

AT+CPMS

“call“

Call in progress (0-1). Indicator value is "1" if at least one call is in state "active"

or "held".

Depending on the parameter

<succ>

selected with

AT^SCFG

the indicator

"call" will be issued
• when a state transition ends in state "active" or state "unknown", if

<succ>

="restricted",

• when any state transition (including transitions beginning or ending in state

"unknown") occurs in the list of active calls or when a traffic channel is

established, if

<succ>

="verbose".

Also refer to Section

7.1

,

Call Status Information

.

“roam“

Roaming indicator (0-1)

0: Registered to home network or not registered

1: Registered to other network

“smsfull“

A short message memory storage in the MT has become full (1) or memory

locations are available (0), i.e. range is (0-1)

“rssi“

Received signal (field) strength (0..5)

0: signal strength <= -112 dbm

1-4: signal strength in 15 dbm steps

5: signal strength >= -51 dbm

Received signal (field) strength can also be obtained with

AT+CSQ

. However,

the signal strength is scaled to value range 0..31 by this command.

0

Indicator is deregistered. The indicator will not be presented as "

+CIEV

" URC,

but can be queried with

AT+CIND

?.

[1]

(&F)(P)

Indicator is registered, indicator event report allowed.

<indDescr>

(str)

<mode>

(num)

Advertising