9 at+cfun set phone functionality, At+cfun set phone functionality, Ac75 at command set – Siemens AC75 User Manual

Page 42

Advertising
background image

AC75 AT Command Set

2.9 AT+CFUN

s

AC75_ATC_V01.002

Page 42 of 569

10/30/06

Confidential / Released

2.9

AT+CFUN Set phone functionality

The

AT+CFUN

command serves to control the functionality level of the ME. It can be used to reset the ME, to

choose one of the SLEEP modes or to return to full functionality.

Intended for power saving, SLEEP mode reduces the functionality of the ME to a minimum and thus minimizes

the current consumption. Further information, particularly power supply ratings during the various operating

modes and the timing of hardware signals in SLEEP mode can be found in the

"AC75 Hardware Interface

Description, Version 01.002"

.

SLEEP mode falls in two categories:
• NON-CYCLIC SLEEP mode

<fun>

=0

• and CYCLIC SLEEP modes, selectable as

<fun>

= 7 or 9.

NON-CYCLIC SLEEP mode permanently blocks the serial interface. The benefit of the CYCLIC SLEEP mode is

that the serial interface remains accessible and that, in intermittent wake-up periods, characters can be sent or

received without terminating the selected mode. This allows the ME to wake up for the duration of an event and,

afterwards, to resume power saving. Please refer to Section

2.9.1

,

Wake up the ME from SLEEP mode

for a

summary of all SLEEP modes and the different ways of waking up the module.

For CYCLIC SLEEP mode both the ME and the application must be configured to use hardware flow control.

This is necessary since the CTS signal is set/reset every 0.9-2.7 seconds in order to indicate to the application

when the UART is active. The default setting of hardware flow control is

AT\Q

0 which must be altered to

AT\Q

3.

For use after restart you are advised to add it to the user profile saved with

AT&W

.

If both interfaces ASC0 and ASC1 are connected, hardware flow control must be set in either application. See

notes below for further detail.

SLEEP mode management if Java is started: The Java Virtual Machine remains active, but also enters the

SLEEP mode. AT commands can be sent from the Java application to the serial interface, no matter which

SLEEP mode was selected. This allows you to control the ME even if it is in NON-CYCLIC SLEEP mode.

The

AT+CFUN

test command returns the values of the supported parameters.

The

AT+CFUN

read command returns the current functionality value.

The

AT+CFUN

write command can be used to reset the ME, to choose one of the SLEEP modes or to return to

full functionality.

Syntax

Test Command

AT+CFUN=?

Response(s)

+CFUN:

(list of supported

<fun>

s) , (list of supported

<rst>

s)

OK

Read Command

AT+CFUN?

Response(s)

+CFUN:

<fun>

OK

Write Command

AT+CFUN=

[

<fun>

[,

<rst>

]]

Response(s)

OK

ERROR

+CME ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

GSM 07.07

-

+

+

+

±

±

±

-

+

-

Advertising