Ac75 at command set – Siemens AC75 User Manual

Page 267

Advertising
background image

AC75 AT Command Set

10.3 AT^SISS

s

AC75_ATC_V01.002

Page 267 of 569

10/30/06

Confidential / Released

- Socket type UDP client URL

"sockudp://'host':'remote udpPort'[;size='byte'][;port='word']"

Parameter "size" (optional):

0: PDU size is variable (default).

1 ... 1500: Fixed PDU size in bytes.

Parameter "port" (optional):

0: Port number will be assigned from service (default).

1 ... 2

16

-1: defines the local port number for the UDP client.

2.

FTP
- FTP client URL (get)

"ftp://'user':'password'@'host':'tcpPort'/'url-path' [;type='a|i|d'] "

Refer to "IETF-RFC 1738".

- FTP client URL (put)

"ftpput://'user':'password'@'host':'tcpPort'/'url-path'/'element name'

[;type='a|i'][;mode='u|a|d'] "

Used parameters:

"host" is mandatory, all other parameters are optional.

If "password" is set then "user" must be set as well.

If "user" is omitted the string "anonymous" is selected for "user" and "pass-

word".

If "password" is omitted the password request is served by an empty string.

If "tcpPort" is omitted the service connects to the FTP default port 21.

If "url-path" contains only the IP address a directory listing is requested.

If "url-path" contains the IP address and has a slash '/' appended a detailed

directory listing is requested.

"type": [a)scii | i)mage | d)irectory]

"mode": [u)nique | a)ppend | d)elete]

"u)nique" selects the FTP Store Unique command to create a file name

unique to the current directory. If the file name is assigned by the server

then the "

^SIS

" URC will appear, indicating

<urcInfoId>

2100 and the

file name.

"d)elete" clears given 'element name'.

If "mode" is omitted "replace mode" is default setting.

3.

HTTP

HTTP client URL

Length: 6 ... 255

"http://'server'/'path':'tcpPort' "

"server": FQDN or IP-address

"path": path of file or directory

"tcpPort": If parameter is omitted the service connects to HTTP default port

80.

Refer to "IETF-RFC 2616".

4.

SMTP SMTP server address (string).

Length: 4 ... 256.

5.

POP3 POP3 server address (string).

Length: 4 ... 256.

hcContent

Optional parameter for HTTP method "Post".

Length: 0 ... 127

Can be used to transfer a small amount of data. The content of this string will

only be sent if "hcContLen" = 0. The maximum length of "hcContent" is 127

bytes.

To transmit a larger amount of data "hcContLen" must be set to a non-zero

value. In this case the "hcContent" string will be ignored, and data transmission

from the client to the server is done with

AT^SISW

.

hcContLen

Mandatory parameter for HTTP method "Post".

Length: 0 ... 2

31

-1

The content length shall be set in the header of the HTTP "Post" request before

the data part is transferred.

If "hcContLen" = 0 then the data given in the "hcContent" string will be posted.

Advertising