Maximum sdu size, Sdu error ratio, Residual bit error ratio – Siemens AC75 User Manual

Page 321: Delivery of erroneous sdus, Maximum sdu, Size, Delivery of erroneous, Sdus, Ac75 at command set

Advertising
background image

AC75 AT Command Set

11.7 AT+CGEQMIN

s

AC75_ATC_V01.002

Page 321 of 569

10/30/06

Confidential / Released

This parameter indicates the maximum allowed SDU size in octets.
[0]

subscribed value

10...1520

(value needs to be divisible by 10 without remainder)

1502

This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous. SDU error ratio

is defined only for conforming traffic. The value is specified as "mEe". As an example a target SDU error ratio

of 5*10

-3

would be specified as "5E3" (e.g.

AT+CGEQMIN

=...,"5E3",...).

[“0E0“]

subscribed value

“1E2“
“7E3“
“1E3“
“1E4“
“1E5“
“1E6“
“1E1“

This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error

detection is requested, Residual bit error ratio indicates the bit error ratio in the delivered SDUs. The value is

specified as "mEe". As an example a target residual bit error ratio of 5*10

-3

would be specified as "5E3" (e.g.

AT+CGEQMIN

=...,"5E3",...).

[“0E0“]

subscribed value

“5E2“
“1E2“
“5E3“
“4E3“
“1E3“
“1E4“
“1E5“
“1E6“
“6E8“

This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0

no

1

yes

2

no detect

[3]

subscribed value

<Maximum SDU size>

(num)

<SDU error ratio>

(str)

<Residual bit error ratio>

(str)

<Delivery of erroneous SDUs>

(num)