Autoexeccmd, Autoexectype, Autoexecindex – Siemens AC75 User Manual

Page 63: Autoexecmode, Autoexec, Ac75 at command set

Advertising
background image

AC75 AT Command Set

2.14 AT^SCFG

s

AC75_ATC_V01.002

Page 63 of 569

10/30/06

Confidential / Released

Parameter Description

AutoExec Command
This parameter serves to switch the Autoexec function on or off.

If it is switched off (

<AutoExecCmd>

=0), parameters following

<AutoExecIndex>

are ignored and all settings

at the given index are restored to their default values.

Value will be saved while switching off the AC75 via AT commands (e.g.

AT+CFUN

or

AT^SMSO

) and restored

on next power up.
“0“

Disable automatic execution of the AT command(s) specified with

<AutoEx-

ecATC>

at a given

<AutoExecIndex>

.

“1“

Enable automatic execution of the AT command(s) specified with

<AutoExe-

cATC>

at a given

<AutoExecIndex>

. Not allowed for

<AutoExecType>

=0

(DTR line activation) while multiplex mode is active, refer to

AT+CMUX

.

AutoExec Event Type
This parameter selects the kind of event used to automatically launch the AT command(s) specified with

<AutoExecATC>

.

Value will be saved while switching off the AC75 via AT commands (e.g.

AT+CFUN

or

AT^SMSO

) and restored

on next power up.
“0“

Autoexec activity is driven by ASC0 DTR line activation (OFF-ON transition).

“1“

Autoexec activity is timer driven. To specify the time span use

<AutoExecPe-

riod>

.

AutoExec Command Index
This parameter specifies the command storage index. The following table shows the index ranges supported for

each variant of

<AutoExecType>

.

Value will be saved while switching off the AC75 via AT commands (e.g.

AT+CFUN

or

AT^SMSO

) and restored

on next power up.

AutoExec Command Mode
0...255
This parameter specifies details regarding the behavior of the AC75 when the AT command starts to be exe-

cuted.

Value is interpreted as a bit field, unused bits are reserved for future use (RFU) and shall be set to 0.

When a call is released by an Autoexec activity, no release indication may be issued on the first logical channel.

Value will be saved while switching off the AC75 via AT commands (e.g.

AT+CFUN

or

AT^SMSO

) and restored

on next power up.

<AutoExecCmd>

(str)(+CSCS)

<AutoExecType>

(str)(+CSCS)

<AutoExecIndex>

(str)(+CSCS)

<AutoExecType>

value

<AutoExecType>

event

Valid Indices

0

Autoexec activity is driven by ASC0 DTR

line activation

0

1

Autoexec activity is timer driven.

0-2

<AutoExecMode>

(str)(+CSCS)

Advertising