AC75 AT Command Set

10.10 AT^SICC

s

AC75_ATC_V01.002

Page 289 of 569

10/30/06

Confidential / Released

10.10

AT^SICC Internet Connection Close

The

AT^SICC

write command releases a connection opened with

AT^SICO

and restores the previously set inac-

tivity timeout "inactTO" of the selected connection profile.

The command returns an error if any services are bound to this profile. Before using the

AT^SICC

write com-

mand be sure that all services were closed with

AT^SISC

.

Syntax

Parameter Description

0...5

Internet connection profile identifier defined with parameter

<conProfileId>

of

AT^SICS

.

Note

• Be sure not to mix up the start and close commands connection profiles and service profiles. It is allowed to

use only the combinations

AT^SICO

/

AT^SICC

or

AT^SISO

/

AT^SISC

.

Test Command

AT^SICC=?

Response(s)

[^SICC:(list of defined

<conProfileId>

s)]

OK

Write Command

AT^SICC=

<conProfileId>

Response(s)

OK

ERROR

+CME ERROR:

<err>

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge