AT+CLVL Loudspeaker volume level

Syntax

Parameter Description

Loudspeaker Volume Level
0...4

(D)

Notes

• The write command can only be used in audio mode 2 - 6.
• The values of the volume steps are specified with the parameters

<outCalibrate>

[0],...

<outCali-

brate>

[4] of the

AT^SNFO

command.

• As an alternative to

AT+CLVL

, you can use

AT^SNFO

and

AT^SNFV

. The parameter

<level>

is identical with

<outStep>

used by both commands.

• Any change to

<level>

(or

<outStep>

) takes effect in audio modes 2 to 6. That is, when you change

<level>

(or

<outStep>

) and then select another mode with

AT^SNFS

, the same step will be applied.

The only exception is audio mode 1 which is fixed to

<level>

=4 (or accordingly

<outStep>

=4).

<level>

(or

<outStep>

) is stored non-volatile when the ME is powered down with

AT^SMSO

or reset with

AT+CFUN

=1,1.

Test Command

AT+CLVL=?

Response(s)

+CLVL:

(list of supported

<level>

s)

OK

Read Command

AT+CLVL?

Response(s)

+CLVL:

<level>

OK

ERROR

+CME ERROR: <err>

Write Command

AT+CLVL=

<level>

Response(s)

OK

ERROR

+CME ERROR: <err>

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

GSM 07.07

-

+

+

+

+

+

+

-

+

-

<level>

(num)