AC75 AT Command Set

13.27 AT^SSDA

s

AC75_ATC_V01.002

Page 400 of 569

10/30/06

Confidential / Released

13.27

AT^SSDA Set SMS Display Availability

This command allows to notify the AC75 of its controlling application's capability to immediately display incoming

SMS on a display.

If the application is able to display incoming short messages, a class 0 message shall be displayed immediately.

However, if it does not, class 0 messages shall be treated as if no message class is determined (GSM 03.38

[20]

).

The effect of this command if

<da>

=1 is to determine the behavior of parameter

<mt>

of

AT+CNMI

:

If multiplex mode is enabled (

AT+CMUX

) and

<da>

=1 with

<mt>

=1 is set on any logical channel, all other chan-

nels have to use

<mt>

=0.

Syntax

Parameter Description

Display Availability
0

(&F)

Application is not able to display incoming short message

1

Application is able to display incoming short message

Note

• If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0/ASC1) avoid different settings for

routing and indicating short messages. For example, if messages shall be routed directly to one instance of

the TE (set with

AT+CNMI

,

AT^SSDA

), it is not possible to activate the presentation of URCs with

AT+CMER

or

AT+CNMI

on another instance. Any attempt to activate settings that conflict with existing settings on

another interface, will result in CME ERROR, or accordingly CMS ERROR.

Test Command

AT^SSDA=?

Response(s)

^SSDA:

list of supported

<da>

s

OK

Read Command

AT^SSDA?

Response(s)

^SSDA:

<da>

OK

Write Command

AT^SSDA=

<da>

Response(s)

OK

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

-

+

+

+

+

+

+

-

+

-

<da>

(num)

Advertising