20 at^scms send concatenated short messages, Ac75 at command set – Siemens AC75 User Manual

Page 392

Advertising
background image

AC75 AT Command Set

13.20 AT^SCMS

s

AC75_ATC_V01.002

Page 392 of 569

10/30/06

Confidential / Released

13.20

AT^SCMS Send Concatenated Short Messages

Sending a concatenated message is similar to sending a "normal" message, except that each segment of the

concatenated message must be identified by the additional parameters

<seq>

,

<ieia>

and

<ref>

. To send all

segments of the message one by one, the

AT^SCMS

write command must be executed for each segment.

The write command transmits one segment of a concatenated short message from TE to network (SMS-SUB-

MIT).

After invoking the write command wait for the prompt ">" and then start to write the message. To send the mes-

sage simply enter

<CTRL-Z>

. After the prompt a timer will be started to observe the input.

To abort sending use

<ESC>

. Abortion is acknowledged with "OK", though the message will not be sent.

The message reference

<mr>

is returned to the TE on successful message delivery. The value can be used to

identify the message in a delivery status report provided as an unsolicited result code.

Syntax

Notes

• See notes provided for

AT+CMGS

.

• Command is only available if

AT+CMGF

=1.

Test Command

AT^SCMS=?

Response(s)

OK

Write Command

Command syntax for text mode (see

AT+CMGF

=1):

AT^SCMS=

<da>

[,

<toda>

],

<seq>

,

<max>

,

<ieia>

,

<ref>

<CR>

Text can be entered

<CTRL-Z>

/

<ESC>

Response(s)

+CMGS:

<mr>

[,

<scts>

]

OK
If sending fails
ERROR

+CMS ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

+

+

+

+

+

+

+

-

-

-

Advertising