AC75 AT Command Set

3.3 AT^SIND

s

AC75_ATC_V01.002

Page 90 of 569

10/30/06

Confidential / Released

The name information received by the NITZ service (type 3) is stored non-volatile. It replaces the operator name

of the registered PLMN (type 4) or its numeric form (type 5) stored in the ME. But if the ME, after restart, registers

to another PLMN that is not equal to the saved NITZ name information, the NITZ name information must be

invalidated. If the type is 2, 4 or 5,

AT+COPS

with the appropriate

<mode>

displays the same operator name.

0

Indicator is deregistered, i.e. no such indicator event report (URC) will be

issued.

<mode>

=0 is power-up and factory default of indicators defined by

AT^SIND

only.

1

Indicator is registered.
• Indicator event reports are controlled via

AT+CMER

.

• All indicators can be registered or deregistered via

AT^SIND

, but different

default settings apply: Power-up and factory default of the indicators sup-

ported by

AT+CIND

is

<mode>

=1, while, as stated above, indicators defined

by

AT^SIND

only are set to

<mode>

=0.

2

Query the registration status and the current value of a single indicator type.

ADN phonebook record number on the SIM.

Phone number, for further details see

AT+CPBR

.

Address type, for further details see

AT+CPBR

.

145

Dialing string

<adnNumber>

includes international access code character '+'.

209

Dialing string

<adnNumber>

contains printable non-alphabetic non-digit char-

acters saved with the number string.

129

otherwise

Text assigned to a phone number. For further details see

AT+CPBR

.

If delivered by the network: Number of new voice messages sent as part of the Voice Message Waiting Indicator.

Refer to

<indDescr>

.

Operator in format which depends on the type associated to the operator name. Refer to

<indValue>

.

Service Provider Name according to the status settings (SIM Service No. 17) in the SIM Service Table (SST) of

the SIM.

Universal Time delivered as part of the "nitz" Indicator. Refer to

<indDescr>

.

5

Broadcast MCC-MNC (numeric format which consists of a 3-digit country code

plus a 2- or 3-digit network code).

<mode>

(num)

<adnEntry>

(num)

<adnNumber>

(str)

<adnType>

(num)

<adnText>

(str)

<vmCounter>

<eonsOperator>

<servProvider>

(str)

<nitzUT>

Advertising