Table 2.3, Ac75 at command set – Siemens AC75 User Manual

Page 45

Advertising
background image

AC75 AT Command Set

2.9 AT+CFUN

s

AC75_ATC_V01.002

Page 45 of 569

10/30/06

Confidential / Released

• Quit: ME exits SLEEP mode.
• Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time

after the last character was sent or received on the serial interface.

• No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

Event

Selected mode:

<fun>

=0

Selected mode:

<fun>

=7 or 9

Ignition line

No effect

No effect

/RTS0 or /RTS1 activation

Quit

Mode 7: No effect (RTS is only

used for flow control)

Mode 9: Temporary

Unsolicited Result Code (URC)

Quit

Temporary

Incoming voice or data call

Quit

Temporary

Any AT command (incl. outgoing

SMS, voice or data call)

From Java: Yes

Without Java: Not possible (UART

disabled)

Temporary

Incoming SMS (

AT+CNMI

is set to

0,0 (this is the default setting)

No effect

No effect

Incoming SMS (

AT+CNMI

is set to

1,1)

Quit

Temporary

GPRS data transfer

From Java: Yes

Without Java: Not possible (UART

disabled)

Temporary

RTC alarm line

Quit

Temporary

AT+CFUN

=1

From Java: Yes

Without Java: Not possible (UART

disabled)

Quit

Java terminates

Quit

Temporary

Advertising