21.2

AT^SJNET Set Dialup Network Access Parameters

The

AT^SJNET

write command allows to create a profile which contains all parameters needed for automated

network access through a dialup connection.

Syntax

Test Command

AT^SJNET=?

Response(s)

^SJNET:

("csd"|"gprs"), ("Tel. num."|"access point name"), ("login"), ("password"), ("dns"), (list of supported

<timeout>

s)

OK

Read Command

AT^SJNET?

Response(s)

^SJNET:

<bearer service>

,

<entry point>

,

<login>

,

<password>

,

<dns>

,

<timeout>

OK

ERROR

+CME ERROR: <err>

Write Command

AT^SJNET=

<bearer service>

,

<entry point>

,

<login>

,

<password>

[

<dns>

][,

<timeout>

]

Response(s)

^SJNET:

<bearer service>

,

<entry point>

,

<login>

,

<password>

,

<dns>

,

<timeout>

OK

ERROR

+CME ERROR: <err>