Nitztz, Nitzdst, Ac75 at command set – Siemens AC75 User Manual

Page 91

Advertising
background image

AC75 AT Command Set

3.3 AT^SIND

s

AC75_ATC_V01.002

Page 91 of 569

10/30/06

Confidential / Released

Time Zone delivered as part of the "nitz" Indicator. Refer to

<indDescr>

.

Adjustment for Daylight Saving Time as part of the "nitz" Indicator. Refer to

<indDescr>

.

Example

Activation and use of indicator "audio":

<nitzTZ>

<nitzDST>

AT^SIND="audio",1

You register the indicator "audio".

^SIND: audio,1,0

OK

AT+CMER=2,,,2

You activate the Indicator Event Report with

AT+CMER

.

OK

A set of all registered URCs is presented. (Please note that the example

includes the indicators registered due to the power-up default settings

of

AT+CIND

.)

+CIEV: battchg,5

+CIEV: signal,0

+CIEV: service,1

+CIEV: sounder,0

+CIEV: message,1

+CIEV: call,0

+CIEV: roam,0

+CIEV: smsfull,0

+CIEV: rssi,4

+CIEV: audio,0

ATD030123456

You make a call.

OK

+CIEV: audio,1

+CIEV: sounder,1

+CIEV: call,1

+CIEV: signal,0

+CIEV: sounder,0

ATH

You hang up.

OK

+CIEV: call,0

+CIEV: rssi,3

+CIEV: audio,0

+CIEV: signal,0

+CIEV: rssi,4