2 homing mode, 11 basic drive functions – Lenze 9400 User Manual

Page 422

Advertising
background image

11

Basic drive functions

11.6

Homing

422

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.2.2

Homing mode

The zero position, also called reference, can be defined by a reference search or reference setting:

• In case of a reference search the drive travels according to a defined mode to detect the

reference independently.

• In case of reference setting the reference is manually set when the drive has stopped.

Tip!
A reference search is mainly used in the case of continuously running systems, or if the

traversing range or machine cycle of the drive cannot be represented in the display area of

the encoder, e. g. if incremental encoders are used at the motor, or singleturn absolute

value encoders or resolvers are used at the gearbox.
A reference is mainly set in systems/machines that bear the risk of collisions, or every time

no homing can be executed (e.g. in case of a cross cutter having material in the machine).

• For reference setting, select the homing mode "100" in

C02640

.

• For a reference search the homing modes 0"..."15" are provided in

C02640

.

• For process descriptions see the chapter "

Overview of the Lenze homing modes

".

( 427)

From software version V3.0

according to the DS402 device profile, additionally the homing

modes 1001"..."1035" are provided in

C02640

. Process descriptions for these homing modes

can be found in the chapter "

Overview of DS402 homing modes

".

( 427)

Note!

Profile data set change-over
For the reference search, two profile data sets with different speeds and accelerations

can be parameterised. In this way, the homing time can be reduced and at the same time

the accuracy can be increased.

Profile data set change-over

( 424)

The process descriptions in the following chapters provide information on the time the

change-over to the profile data set 2 takes place in the corresponding homing mode.

Overview of the Lenze homing modes

( 427)

Overview of DS402 homing modes

( 440)

If the speed 2 (

C02646

) is set to "0" (Lenze setting), no change-over to the profile data set

2 takes place and the reference search and positioning to the target position is only

executed with the profile parameters of the profile data set 1.

Note!

Drive behaviour after setting the reference

From software version V4.0 onwards

,

C02641

serves to parameterise the drive

behaviour after setting the home position.

Drive behaviour after setting the home position

( 423)

In the Lenze setting (

C02641

= "0"), the drive traverses to the absolute target position set

in

C02643

similarly to the behaviour known from the previous versions.