Mode 14: positive direction to torque limit

Procedure:

1. Movement in a positive direction with reduced torque and profile data set 1.
2. The reference is set if the two following conditions for the time set in

C02650

are fulfilled at the

same time:

• The current speed is lower than the threshold for standstill detection set in

C00019

.

• Current torque is greater than the torque limit set in

C02649

("Homing to end stop").

3. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

Mode 15: negative direction to torque limit

Procedure:

1. Movement in a negative direction with reduced torque and profile data set 1.
2. The reference is set if the two following conditions for the time set in

C02650

are fulfilled at the

same time:

• The current speed is lower than the threshold for standstill detection set in

C00019

.

• Current torque is greater than the torque limit set in

C02649

("Homing to end stop").

3. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641