11.14

Pole position identification

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.14.5

Impacts of parameter changes on the signal PPI_bPolePositionAvailable

Changing the type of motor control (C00006)

Changing relevant motor data

Changing relevant encoder data

Initial situation 1

Parameter change

Impact

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) = "1: SC:

Servo control sync. motor"

In

C00006

another motor control is

set.

PPI_bPolePositionAvailable remains

on TRUE since the signal is irrelevant

for an asynchronous motor.

Initial situation 2

Parameter change

Impact

PPI_bPolePositionAvailable = TRUE

• Motor control (

C00006

) =

• "2: SC: Servo control async.

motor" or

• "4: SLVC: Sensorless vector

control" or

• "6: VFCplus: V/f control" or

• "7: VFCplus: V/f control"

In

C00006

, the motor control "1: SC:

Servo control sync. motor" is set.

PPI_bPolePositionAvailable is reset to

FALSE since the signal is relevant for a

synchronous motor and apparently a

new motor has been selected.

Initial situation

Parameter change

Impact

PPI_bPolePositionAvailable = TRUE

One of the following parameters is

changed:

• Rated motor speed (

C00087

)

• Rated motor frequency (

C00089

)

• Rated motor voltage (

C00090

)

PPI_bPolePositionAvailable is reset to

FALSE since it is assumed that the

connected motor has been changed.

Initial situation

Parameter change

Impact

PPI_bPolePositionAvailable = TRUE

One of the following parameters is

changed:

• Resolver - number of pole pairs

(

C00080

)

• Encoder - number of increments

(

C00420

)

• Encoder type (

C00422

)

• TTL encoder signal evaluation

(

C00427

)

• Motor encoder selection (

C00495

)

PPI_bPolePositionAvailable is reset to

FALSE.