Altera Arria V Hard IP for PCI Express User Manual
Page 24
2–8
Chapter 2: Getting Started with the Arria Hard IP for PCI Express
Customizing the Endpoint in the MegaWizard Plug-In Manager Design Flow
Arria V Hard IP for PCI Express
December 2013
Altera Corporation
User Guide
4. To display the parameters of the APPS component shown in the previous figure,
click on it and then select Edit from the right-mouse menu
Figure 2–4
. illustrates
this component. Note that the values for the following parameters match those set
in the DUT component:
■
Targeted Device Family
■
Lanes
■
Lane Rate
■
Application Clock Rate
■
Port
■
Application interface
■
Tags supported
■
Maximum payload size
■
Number of Functions
1
You can use this Qsys APPS component to test any Endpoint variant with
compatible values for these parameters.
5. To close the APPS component, click the X in the upper right-hand corner of the
parameter editor.
Go to
“Simulating the Example Design ###avst_sim###” on page 2–11
for instructions
on system simulation.
Figure 2–4. Qsys Component Representing the Chaining DMA Design Example