Logs

Configuring Loudness Analysis Parameters

186

Configuring Loudness Analysis Parameters

There are three loudness analysis parameters you may configure:

• Loudness standard

• Relative gating

• Short-term window

See also

For more information about Audio Loudness Analyzer and relevant tasks (including more
detail about the

As-Run

log file), see the Audio Loudness Analyzer User Manual, available by

clicking Help in Audio Loudness Analyzer.

Configurable loudness analysis parameters

Parameter

name

Description

Data set

Standard

The program compliance loudness standard against which the loudness data will be
measured.

G8 refers to the now-obsolete version of EBU-R128 recommending a gate value of -

8LU. The currently recommended value is -10LU.

• A85 1770-1 leaves the threshold level up to broadcasters and recommends an anchor

when available and a gate if necessary (used in USA, Canada).

• A85 1770-2 recommends a gate is ALWAYS enabled, having a threshold set to -10LU

(used in the European Union).

• ARIB TR-B32 is based on A85 1770-2 with a recommended threshold of -24LKFS

(absolute gate at -70LKFS, -10LU relative gate, 400ms sample blocks).

• EBU G8

• EBU G10

• ARIB TR-B32

• A85 1770-1

• A85 1770-2