Grass Valley iControl V.6.02 User Manual

Page 499

Advertising
background image

iControl

User Guide

489

When the page next attempts to refresh (or when you manually click the Refresh button) it
will be unable to retrieve data because the configured Backup no longer has a current
IP address.

3. Wait about 1 minute.

4. In your browser’s address bar, type the Extra IP address (noted in

step 1

) to connect to the

taken-over configured Main (now Offline).

5. Navigate to the iControl—Redundancy configuration page (see

page 559

).

6. If you observe the following, the manual takeover was a success:

In the row corresponding to the taken-over configured Main (now Offline):

the color of the row is yellow

the Current IP is the same as the configured Extra IP (or the factory default IP:
10.0.3.6 if no Extra IP is configured)

the Operational State is Offline

the Auto-failover function is disabled

In the row corresponding to the configured Backup (now Online):

the color of the row is yellow (indicating a Manual Takeover or Failover has occurred)

the Current IP is the IP of the Main Application Server that was taken over

the Operational State is Online

Advertising