Basic parameter view – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 112

Advertising
background image

112

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

Chapter 3

Programming and Parameters

Basic Parameter View

Parameter 211 [Param Access Lvl] set to option 0 “Basic”.

File

Group

Parameters

Monitor

Speed Meters

[Speed Ref A]

44

[Speed Ref A Pct]

47

[Speed Ref B]

48

[Speed Ref B Pct]

49

[Speed Ref Out]

385

[Spd Ref Out Pct]

384

[Ramp In]

110

[Ramp In Pct]

111

[Ramp Out]

113

[Ramp Out Pct]

114

[Speed Draw Out]

1018

[Spd Draw Out Pct]

1019

[Droop Out]

1006

[Droop Out Pct]

1007

[Speed Reg In]

118

[Speed Reg In Pct]

117

[Spd Reg Err]

1010

[Spd Reg Err Pct]

1011

[Spd Reg Fdbk]

1008

[Spd Reg Fdbk Pct]

1009

[Spd Feedback]

122

[Spd Feedback Pct]

121

[Actual Speed]

924

[Encoder Speed]

420

[Tachometer Speed]

1408

[Resolver Speed]

428

Current Meters

[Inertia Comp Out]

232

[Spd Reg Out Pct]

236

[Current Reg In]

41

[Arm Current]

200

[Arm Current Pct]

199

[Field Current]

351

[Fld Current Pct]

234

[Cur Lim Pos Out]

10

[Cur Lim Neg Out]

11

[Filt TorqCur Pct]

928

[Flux Ref Pct]

500

[Field Curve Out]

476

[Selected TorqRef]

14

[Motor Trq Ref]

17

Drive Data

[FaultCode]

57

[AC Line Voltage]

466

[AC Line Freq]

588

[Output Voltage]

233

[Output Power]

1052

[Drive Type]

300

[Drive Size]

465

[Elapsed Lifetime]

235

[Software Version]

331

Motor Control

Motor Data

[Max Ref Speed]

45

[Max Feedback Spd]

162

[Rated Motor Volt]

175

[Nom Mtr Arm Amps]

179

[Nom Mtr Fld Amps]

280

[Drv Fld Brdg Cur]

374

Field Config

[Field Reg Enable]

497

[Field Economy En]

499

[Field Econ Delay]

1407

[Field Mode Sel]

469

[Max Fld Curr Pct]

467

[Min Fld Curr Pct]

468

[Fld Weaken Ratio]

456

Torq Attributes

[Current Limit]

7

[Current Lim Pos]

8

[Current Lim Neg]

9

[Torque Ref]

39

[Trim Torque]

40

[Torque Reduction]

342

[Zero Torque]

353

Speed Feedback

[Fdbk Device Type]

414

[Anlg Tach Gain]

562

[Feedback Offset]

563

[Spd Fdbk Control]

457

[SpdReg FB Bypass]

458

Autotune

[Autotune Cur Lim]

1048

[CurrReg Autotune]

452

[Arm Resistance]

453

[Arm Inductance]

454

[Spd Reg Autotune]

1027

[Speed Tune Dir]

1029

[Speed Tune Kp]

1032

[Speed Tune Ki]

1033

[Spd Tune Inertia]

1030

[SpdTune Friction]

1031

Speed Command

Limits

[Minimum Speed]

1

[Min Speed Fwd]

5

[Min Speed Rev]

6

[Maximum Speed]

2

[Max Speed Fwd]

3

[Max Speed Rev]

4

Discrete Speeds

[Jog Speed]

266

[Jog Off Delay]

1409

[Preset Speed 1]

154

[Preset Speed 2]

155

[Preset Speed 3]

156

[Preset Speed 4]

157

[Preset Speed 5]

158

[Preset Speed 6]

159

[Preset Speed 7]

160

[TB Manual Ref]

267

Speed References

[Trim Ramp]

42

[Trim Ramp Pct]

378

[Trim Speed]

43

[Trim Speed Pct]

379

[Speed Ratio]

1017

Speed Regulator

[Speed Reg En]

242

(1)

[Arm Volt Kp]

493

[Arm Volt Ki]

494

[Spd Reg Kp]

87

[Spd Reg Ki]

88

(1) This parameter available for use with firmware version 2.005 and lower only.

Dynamic Control

Control Config

[Spd Trq Mode Sel]

241

Ramp Rates

[Speed Ramp En]

245

[Ramp Type Select]

18

[Accel Time 1]

660

[Decel Time 1]

662

[Accel Time 2]

24

[Decel Time 2]

32

[MOP Accel Time]

22

[MOP Decel Time]

30

[Jog Ramp Time]

1410

[S Curve Time]

19

Restart Modes

[Start At Powerup]

1344

[Powerup Delay]

1345

Monitor

Motor Control

Speed Comm

and

Dynamic Control

Advertising