Pid function – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 275

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

275

Application Notes

Appendix C

PID Function

The PID function is used to increase or reduce the reference signal output to the
speed or current regulator of the drive. The PID function can be used for nip-
roll, winder/unwinder, roll doctor/salvage machine, pump and extruder pressure
control and extruder temperature control applications. (See the complete “PID
Control” block diagram on page

330

.)

Examples are included below for configuring the following applications:

Speed winder with a load cell and tension control

❏ Line speed signal (see Configure a Line Speed Signal on page

276

)

❏ Closed loop dancer / load cell feedback (see Configure the Feedback

Signal in the Follower Drive(s) on page

277

)

❏ Tension set point (see Configure the Tension Set Point Signal in the

Follower Drive(s) on page

279

)

Torque winder with a load cell and tension control

❏ Line speed signal (see Configure a Line Speed Signal on page

276

)

❏ Closed loop dancer / load cell feedback (see Configure the Feedback

Signal in the Follower Drive(s) on page

277

)

❏ Tension set point (see Configure the Tension Set Point Signal in the

Follower Drive(s) on page

279

)

Advertising