Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 181

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

181

Programming and Parameters

Chapter 3

INPUT

/ O

U

TPU

T

An

al

og In

pu

ts

1045

[Anlg In1 Cmp Eq]

Provides an indication, after the amount of time specified in Par 1044 [Anlg
In1 Cmp Dly] has elapsed, when the value set in parameter 1043 [Anlg In1
Cmp Err] has been reached.
“0” = The value of analog input 1 is above or below the value set in Par

1043 [Anlg In1 Cmp Err].

“1” = The value of analog input 1 is within the range set in Par 1043

[Anlg In1 Cmp Err].

Notes: This parameter can be assigned to a digital output. See Analog Input
Signal Comparison on
page

263

for more information.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

1042,
1043,
1044

1404

[Analog In1 Value]

Value of the signal at analog input 1. Units based on the value set in Par 71
[Anlg In1 Config].

Default:

Min/Max:
Units:

Read Only

-/+20.00
V or mA

Real

71

1405

[Analog In2 Value]

Value of the signal at analog input 2. Units based on the value set in Par 76
[Anlg In2 Config].

Default:

Min/Max:
Units:

Read Only

-/+20.00
V or mA

Real

76

1406

[Analog In3 Value]

Value of the signal at analog input 3. Units based on the value set in Par 81
[Anlg In3 Config].

Default:

Min/Max:
Units:

Read Only

-/+20.00
V or mA

Real

81

An

alog O

utpu

ts 62

63
64
65

[Anlg Out1 Scale]
[Anlg Out2 Scale]
[Anlg Out3 Scale]
[Anlg Out4 Scale]

Scaling of the analog outputs.

Default:

Min/Max:

1.00

–/ +10.00

Real

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

Advertising