20p-um001f-en-p, june 2009, 20p-um001e-en-p, november 2008 – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 353

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

353

History of Changes

Appendix I

20P-UM001F-EN-P, June 2009

20P-UM001E-EN-P,
November 2008

Change
Updated the Catalog Number Explanation to reflect new drive ratings.
Added frame D dimensions and weights.
Added lifting instructions for frame D drives.
Added instructions for opening frame D drives.
Added CE Conformity information for frame D drives and updated the emissions limits table.
Added Control Power Protection information for frame D drives and updated information for rev. “I” and above control
power circuit boards.
Updated the AC Input and DC Output Voltage tables for 575V and 690V drives.
Updated the Typical Power Wiring diagrams to include isolation transformer/line reactor requirements.
Updated the Armature Converter Connections section for frame D.
Updated the Armature Voltage Feedback Connections section for frame D drives.
Updated the Field Circuit Connections section for frame D drives.
Updated the S14 DIP switch settings for the field current configuration.
Updated the frame C heatsink cooling fans connection information.
Added frame D heatsink cooling fans connection information.
Updated the Armature Fuse Signal Terminals information for frame D drives.
Updated Table 24 to include examples of the jumper and switch settings.
Updated the S15 DIP Switch Configuration section to include frame D drives.
Updated relevant I/O Wiring Examples to include required DIP Switch settings.
Added illustration for frame D drive field power and I/O wire routing.
Updated the “Heatsink OvrTemp” (F8) fault action to include fuse location information.
Updated the possible causes for the “Sustained Curr” (F70) fault.
Updated the “Electrical” specifications.
Updated the Encoder Pulses Per Revolution range.
Added Watts Loss tables for frame D drives.
Updated all Drive Power Circuit Protection tables for 575 and 690V AC input and frame D drives.
Updated the Control Power Circuit Protection Fuses table for frame D drives and updated information for rev. “I” and
above control power circuit boards.
Added replacement fuse table for frame D overvoltage clipping board.
Added AC Input Line Reactors and AC Input Contactors for frame D drives.
Added a table for recommended Isolation Transformers.
Added Dynamic Brake Resistor Kits and DC Output Contactors for frame D drives.
Added the Alternate EMC Filters tables.
Added the Terminal Adapter Kits for frame D drives.
Updated the “Installing a Communication Adapter” appendix for frame D drives.

Change
Added information on how to find your drive frame size and firmware revision level.
Updated the Catalog Number Explanation to reflect drive availability.
Added CE Conformity information.
Updated the “Typical Wiring Diagrams” section to reflect the addition of the new Armature Voltage Feedback terminal
block.
Added the Armature Voltage Feedback Connections section.
Updated the S14 DIP switch settings for the field current configuration.
Updated Table 1.L to include examples of the jumper and switch settings.
Updated relevant I/O Wiring Examples to include required DIP Switch settings.
Updated the Drive Start-Up procedures.
Corrected a parameter reference in the definition for parameter 121 [Spd Feedback Pct].
Corrected a parameter reference in the definition for parameter 924 [Actual Speed].
Added parameter 14 [Selected TorqRef] to the Monitor file, Current Meters group.
Added parameter 17 [Motor Trq Ref] to the Monitor file, Current Meters group.
Renamed parameter 500 from [Field Ref Pct] to [Flux Ref Pct].
Corrected a parameter reference in the definition for parameter 928 [Filt TorqCur Pct].