Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

169

Programming and Parameters

Chapter 3

UTILIT

Y

Diagn

os

ti

cs

1402 [Last Stop Source]

Displays the source that initiated the most recent stop sequence.

Default:

Options:

0 =
1 - 5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =
13 =

Read Only

“Pwr Removed”
“DPI Port 1-5”
“Reserved”
“Digital In”
“Fault”
“Not Enabled”
“Reserved”
“Jog”
“Selftune”
“Reserved”

16-bit
Int

1403 [Start Inhibits]

Displays the inputs currently preventing the drive from starting. For each bit, 1=Inhibit condition true and 0=Inhibit condition false.

Fa

ul

ts

263

[Clear Fault Que]

Allows you to clear the fault queue. See Chapter 4 Troubleshooting on page

199

for

information on clearing the fault queue.

Default:

Options:

0 =

0 =
1 =

“Ready”

“Ready”
“Clr Flt Que”

16-bit
Int

1347 [Fault Clear]

Allows you to reset drive faults and/or clear the fault queue.

Default:

Options:

0 =

0 =
1 =
2 =

“Ready”

“Ready”
“Clear Faults”
“Clr Flt Que”

16-bit
Int

1348 [Fault Clr Mode]

Enables/Disables a fault reset (clear faults) attempt from any source. This does not
apply to fault codes which are cleared indirectly via other actions.

Default:

Options:

1 =

0 =
1 =

“Enabled”

“Disabled”
“Enabled”

16-bit
Int

1349 [Status1 at Fault]

Captures and displays Par 381 [Drive Status 1] bit pattern at the time of the last fault. 0=Condition False, 1=Condition True.

381

1350 [Status2 at Fault]

Captures and displays Par 382 [Drive Status 2] bit pattern at the time of the last fault. 0=Condition False, 1=Condition True.

382

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

Options

Re

se

rv

ed

Re

se

rv

ed

DPI P

or

t 5

DPI P

or

t 4

DPI P

or

t 3

DPI P

or

t 2

DPI P

or

t 1

Di

gi

ta

l I

n

Re

se

rv

ed

Star

tup A

ct

v

Re

se

rv

ed

St

op A

ss

er

td

Re

se

rv

ed

Enable

Ty

pe

2

A

la

rm

Fa

ul

t

Default

x

x

x

0

0

0

0

0

x

0

0

1

x

0

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Options

Spd

R

ef

ID 3

Spd

R

ef

ID 2

Spd

R

ef

ID 1

Spd

R

ef

ID 0

Lo

ca

l I

D 2

Lo

ca

l I

D 1

Lo

ca

l I

D 0

At

S

pe

ed

Fa

ul

te

d

Alarm

Dec

el

er

at

in

g

Acc

el

erat

in

g

Ac

tu

al

D

ir

Co

mmand D

ir

Ac

tiv

e

Re

ad

y

Default

0

0

0

0

1

1

1

0

1

0

0

0

1

1

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Aut

o T

uning

Cu

rr

Limit

St

op

ping

Joggi

ng

Ru

nni

ng

Ac

tiv

e

Re

ad

y

Default

x

x

x

x

x

x

x

x

x

0

0

0

1

1

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Advertising