Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

Chapter 3

Programming and Parameters

UTILIT

Y

Us

er

D

ef

in

ed

520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535

[UsrDefBitWrdA0]
[UsrDefBitWrdA1]
[UsrDefBitWrdA2]
[UsrDefBitWrdA3]
[UsrDefBitWrdA4]
[UsrDefBitWrdA5]
[UsrDefBitWrdA6]
[UsrDefBitWrdA7]
[UsrDefBitWrdA8]
[UsrDefBitWrdA9]
[UsrDefBitWrdA10]
[UsrDefBitWrdA11]
[UsrDefBitWrdA12]
[UsrDefBitWrdA13]
[UsrDefBitWrdA14]
[UsrDefBitWrdA15]

Bit variables. The individual "User Defined" bits can be read or written to. It is
possible to process a word with Par 519 [UsrDefBitWrdA] (see example).
Note: You can read bits 0…7 of a digital input with Par 519 [UsrDefBitWrdA] and
write all of the bits associated with [UsrDefBitWrdA] to a digital output.

Default:

Min/Max:

0

0 / 1

16-bit
Int

519

536

[UsrDefBitWrdB]

A bitmap of Pars 537 [UsrDefBitWrdB0] through 552 [UsrDefBitWrdB15]. With a
parameter it is possible to read or write all of the bits inside a word.
Example:

[UsrDefBitWrdB0]

0

[UsrDefBitWrdB1]

1 = 2

1

=2

[UsrDefBitWrdB2]

0

[UsrDefBitWrdB3]

0

[UsrDefBitWrdB4]

0

[UsrDefBitWrdB5]

1 = 2

5

= 32

[UsrDefBitWrdB6]

1 = 2

6

= 64

[UsrDefBitWrdB7]

0

[UsrDefBitWrdB8]

0

[UsrDefBitWrdB9]

0

[UsrDefBitWrdB10]

1 = 2

10

= 1024

[UsrDefBitWrdB11]

0

[UsrDefBitWrdB12]

1 = 2

12

= 4096

[UsrDefBitWrdB13]

0

[UsrDefBitWrdB14]

0

[UsrDefBitWrdB15]

0

[UsrDefBitWrdB] = 2 + 32 + 64 + 1024 + 4096 = 5218

Notes: The value of bits 0…7 of this parameter can be written to digital outputs
1…8, sequentially. In other words, when parameters 145 [Digital Out1
Sel]…152 [Digital Out8 Sel] are assigned option 12 “UserDefinedB”, bit 0 of this
parameter is written to digital output 1, bit 1 is written to digital output 2, bit 2 is
written to digital output 3, etc.

Bits 14 and 15 of this parameter are written to relay outputs 1 and 2, respectively,
when parameters 1392 [Relay Out 1 Sel] and 629 [Relay Out 2 Sel] are assigned
option 12 “UserDefinedB”

Default:

Min/Max:

0

0 / 65535

16-bit
Int

537 -