Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 167

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

167

Programming and Parameters

Chapter 3

U

TIL

IT

Y

Di

ag

n

os

ti

cs

397

[MOP Dec Active]

Indicates whether the drive is decelerating using the preselected ramp.
0 “No Decel” = The drive is not decelerating using a preselected ramp
1 “Decel” = The drive is decelerating using a preselected ramp

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

400

[Spd Select 0]

Indicates the state of the assigned digital input, [Digital Inx Sel], set to 17 “Speed
Sel 1”. See Option Definitions for [Digital Inx Sel] on page

184

for instructions on

how to set digital input speed selects to different speed references.
“0” = Digital input [Digital Inx Sel] set to 17 “Speed Sel 1” not asserted
“1” = Digital input [Digital Inx Sel] set to 17 “Speed Sel 1” asserted
Note: By default, the state of this parameter is determined by digital input 5.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

401,
402

401

[Spd Select 1]

Indicates the state of the assigned digital input, [Digital Inx Sel], set to 18 “Speed
Sel 2”. See Option Definitions for [Digital Inx Sel] on page

184

for instructions on

how to set digital input speed selects to different speed references.
“0” = Digital input [Digital Inx Sel] set to 18 “Speed Sel 2” not asserted
“1” = Digital input [Digital Inx Sel] set to 18 “Speed Sel 2” asserted
Note: By default, the state of this parameter is determined by digital input 6.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

400,
402

402

[Spd Select 2]

Indicates the state of the assigned digital input, [Digital Inx Sel], set to 19 “Speed
Sel 3”. See Option Definitions for [Digital Inx Sel] on page

184

for instructions on

how to set digital input speed selects to different speed references.
“0” = Digital input [Digital Inx Sel] set to 19 “Speed Sel 3” not asserted
“1” = Digital input [Digital Inx Sel] set to 19 “Speed Sel 3” asserted
Note: By default, the state of this parameter is determined by digital input 7.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

400,
401

403

[Ramp Select 0]

Indicates the state of the assigned digital input, [Digital Inx Sel], set to 25 “Acc2 &
Dec2” or 26 “Accel 2”.
“0” = Accel 1 ramp rate is selected
“1” = Accel 2 ramp rate is selected
Note: This parameter can be assigned to indicate the state of a digital input.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

404

404

[Ramp Select 1]

Indicates the state of the assigned digital input, [Digital Inx Sel], set to 25 “Acc2 &
Dec2” or 27 “Decel 2”.
“0” = Decel 1 ramp rate is selected
“1” = Decel 2 ramp rate is selected
Note: This parameter can be assigned to indicate the state of a digital input.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

403

432

[Reslvr Error Cnt]

Increments (16-bit unsigned) for every SSI communication message that contains
an error (for example, CRC). The value of this parameter is reset to zero at drive
power-up or when the “Clear Faults” function is used.
Note: This parameter was added for firmware version 5.002.

Default:

Min/Max:

0

0 / 65536

Read
Only

651

[Spd Fdbk State]

Indicates the status of the selected speed feedback device (DC tach, encoder, or
resolver). A speed feedback loss can be configured as a fault or alarm in Par 478
[Spd Loss Flt Cfg].
“0” = Error
“1” = OK
Notes: This parameter can be assigned to a digital output. The name of this
parameter was changed from [Encoder State] for firmware version 5.002.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

414,
478

1290 [MtrOvrld Status]

Current percentage of motor overload (100% = motor overload). The current
percentage displays regardless of the configuration of the motor overload
condition (Par 479 [MtrOvrld Flt Cfg] = Fault, Alarm, or Ignore).
Note: This parameter was added for firmware version 3.001.

Default:

Min/Max:
Units:

Read Only

0 / 100
%

Real

376,
479

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

A

A

A

A

A

A

Advertising