342

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

Appendix E

Installing a Communication Adapter

5.

Secure and ground the Communication Adapter to the EMI Shield on the
drive using the four captive screws.

6.

Connect the Internal Interface cable to the DPI connectors on the control
board and the communication Adapter board.

7.

Refer to the Adapter’s User Manual for network connection,
commissioning, and configuration information.

8.

Install the HIM Communication cable in reverse order or removal.

9.

Install the drive covers in reverse order of removal.

IMPORTANT

All screws must be tightened, because the adapter is grounded
through a screw to the EMI shield. Recommended tightening torque is
0.9 N•m (8 lb•in).

=

Secure adapter to
EMI Shield with four
(4) screws.

Connect cable to DPI
connectors on adapter
and control board.