Programming and Parameters

Chapter 3

APPL

IC

AT

IONS

D

iamet

er Calc

798

[Dancer Constant]

The measurement corresponding to the total bunching of the material in the
dancer.

Default:

Min/Max:
Units:

1

1 / 10000
mm

16-bit
Int

799

[Minimum Diameter]

Minimum value of the roll diameter.

Default:

Min/Max:
Units:

100

1 / 2000
mm

16-bit
Int

800

[Diameter Calc St]

Status of the initial diameter calculation.
“0” = The initial diameter calculation has not completed.
“1” = The initial diameter calculation has completed.
Note: This parameter can be assigned to a digital output.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

799

[Minimum Diameter]

Minimum value of the roll diameter.

Default:

Min/Max:
Units:

100

1 / 2000
mm

16-bit
Int

1153 [Max Diameter]

Maximum roll diameter.

Default:

Min/Max:
Units:

1.00

0.00 / 32.00
m

Real

1154 [Roll Diameter]

Displays the calculated roll diameter. Note: This parameter can be assigned to an
analog output as a percentage of Par 1153 [Max Diameter].

Default:

Min/Max:
Units:

Read Only

0.00 / 32.00
m

Real

1155 [Line Spd Thresh]

Line speed detecting threshold. When the value of Par 1286 [Ref Line Speed] is
lower than the value of [Line Spd Thresh], the diameter calculation stops and the
diameter is kept at a constant value. When the value of [Ref Line Speed] overcomes
the threshold, the diameter calculation is enabled with an initial filter
corresponding to the value in Par 1206 [Diam Init Filter] for the time set in Par 1207
[Diam Stdy Delay]. At the end of this time the filter will be set to the value of Par
1162 [Diameter Filter].

Default:

Min/Max:
Units:

5.00

0.00 / 150.00
%

Real

1162,
1206,
1207,
1286

1156 [Line Spd Gain]

Calibration value used to obtain Par 1160 [Line Speed Pct] = 100% at its maximum
value. The value of this parameter depends on the value of Par 1284 [Ref Spd
Source]:
[Line Spd Gain] = [32768 x 16384 / (maximum value of [Ref Spd Source] x 8)] -1

Default:

Min/Max:

0

0 / 32767

16-bit
Int

1160,
1284

1157 [Diameter Reset]

Diameter reset. When this parameter is set to “1”, the diameter starting value is set
to the value in Par 1168 [Diam Preset Sel].

Default:

Min/Max:

0

0 / 1

16-bit
Int

1168

1158 [Diam Threshold]

Diameter threshold as a percentage of Par 1153 [Max Diameter]. Par 1159
[Diameter Reached] is set to “1” when the value in this parameter is exceeded.

Default:

Min/Max:
Units:

10.00

0.00 / 150.00
%

Real

1153,
1159

1159 [Diameter Reached]

Indication that the diameter threshold set in Par 1158 [Diam Threshold] has been
exceeded.
“0” = The diameter threshold has not been exceeded.
“1” = The diameter threshold has been exceeded.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

1158

1160 [Line Speed Pct]

Line speed.

Default:

Min/Max:
Units:

Read Only

0.00 / 150.00
%

Real

1161 [Diam Calc Dis]

Enables/Disables the diameter calculation (see also Par 1155 [Line Spd Thresh]).
The last calculated diameter value is saved if this parameter is changed to 0 “Off”
while the diameter is being calculated.

Default:

Options:

1 =

0 =
1 =

“On”

“Off”
“On”

16-bit
Int

1155

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

A

A

A

A

A

A

A

A

A

A

Advertising