Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 121

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

121

Programming and Parameters

Chapter 3

MONIT

O

R

Sp

ee

d Me

te

rs

1010

[Spd Reg Err]

Speed Regulator Error signal, the difference between Par 118 [Speed Reg In]
and 1008 [Spd Reg Fdbk].
Note: This parameter was added for firmware version 4.001.

Default:

Min/Max:
Units:

Read Only

–/+8192
rpm

16-bit
Int

118,
1008

1011

[Spd Reg Err Pct]

Par 1010 [Spd Reg Err] shown as a percentage of Par 45 [Max Ref Speed].
Note: This parameter was added for firmware version 4.001.

Default:

Min/Max:
Units:

Read Only

–/+200.0
%

Real

45

1018

[Speed Draw Out]

Speed draw output value.
Notes: This parameter can be assigned to an analog output. See Speed Draw
Function on page

293

for more information.

Default:

Min/Max:
Units:

Read Only

–/+ Par 45 [Max Ref Speed]

1

rpm

16-bit
Int

45

(1)

The value of [Max Ref Speed] cannot exceed 8192 rpm.

1019

[Spd Draw Out Pct]

Speed draw output as a percentage of Par 45 [Max Ref Speed].
Notes: This parameter can be assigned to an analog output. The min. and
max. values of this parameter were changed from –/+100.00 for firmware
version 3.001.

Default:

Min/Max:
Units:

Read Only

–/+100.0
%

Real

45

1408

[Tachometer Speed]

Actual speed measured by the DC analog tachometer.
Note: The min. and max. values of this parameter were changed from –/
+32770 for firmware version 3.001

Default:

Min/Max:
Units:

Read Only

–/+8192
rpm

Real

Current Met

ers

10

[Cur Lim Pos Out]

Displays the value of the current limit for the positive torque direction as a
percentage of the value in Par 179 [Nom Mtr Arm Amps].

Default:

Min/Max:
Units:

Read Only

0 / 250
%

Real

179

11

[Cur Lim Neg Out]

Displays the value of the current limit for the negative torque direction as a
percentage of the value in Par 179 [Nom Mtr Arm Amps].

Default:

Min/Max:
Units:

Read Only

0 / 200
%

Real

179

14

[Selected TorqRef]

Displays the selected torque reference based on Par 241 [Spd Trq Mode Sel]
value. Scaled as a percentage of Par 179 [Nom Mtr Arm Amps].
Note: This parameter was added for firmware version 3.001.

Default:

Min/Max:
Units:

Read Only

–/+250
%

Real

179,
241

17

[Motor Trq Ref]

Displays the total motor torque reference. Scaled as a percentage of Par 179
[Nom Mtr Arm Amps].
Note: This parameter was added for firmware version 3.001.

Default:

Min/Max:
Units:

Read Only

–/+250
%

Real

179

41

[Current Reg In]

Total current reference value expressed as a percentage of the value in Par
179 [Nom Mtr Arm Amps].
Note: This parameter can be assigned to an analog output.

Default:

Min/Max:
Units:

Read Only

–/+250
%

Real

179

89

[SpdReg PosLmOut]

Indication of the positive limit value in effect on the output of the speed
regulator.
Note: This parameter was added for firmware version 5.002.

Default:

Min/Max:
Units:

Read Only

–/+250
%

Real

90

[SpdReg NegLmOut]

Indication of the negative limit value in effect on the output of the speed
regulator.
Note: This parameter was added for firmware version 5.002.

Default:

Min/Max:
Units:

Read Only

–/+250
%

Real

199

[Arm Current Pct]

Armature current expressed as a percentage of the value in Par 179 [Nom Mtr
Arm Amps].
Note: This parameter can be assigned to an analog output and is the default
selection for Par 67 [Anlg Out2 Sel].

Default:

Min/Max:
Units:

Read Only

–/+250
%

16-bit
Int

179

200

[Arm Current]

Armature current in Amperes.
Note: This parameter can be assigned to an analog output.

Default:

Min/Max:
Units:

Read Only

–/+2.5 x [Nom Mtr Arm Amps]
A

Real

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted