Specifications – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 212

Advertising
background image

212

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

Appendix A

Supplemental Drive Information

Specifications

Category

Specification

Agency
Certification

According to file E59272 for the series of the approved devices.

In conformity with the following European Directives:

EMC Directive (2004/108/EC)
Low Voltage Directive (2006/95/EC)

Standards applied:

EN 50178: 1997
EN 61800-3: 2004

Australian Communications and Media Authority
In conformity with the following:

Radio communications Act: 1992
Radio communications Standard: 2008
Radio communications Labelling Notice: 2008

Standards applied:

EN 61800-3:2004

The drive is also designed to meet the following specifications:
NFPA 70 - US National Electrical Code

Category

Specification

Drive Type

Full Wave Regen, 6 Pulse, Regulated Field Supply

Protection

Heat Sink Thermistor:

Monitored by microprocessor overtemp trip

Drive Armature Overcurrent Trip

Software Overcurrent Trip:
Hardware Overcurrent Trip:

Programmable, 0…250% of rated current (175% default)
Based on armature circuit fusing

Line Transients:

Up to 2000 volts peak per IEC 6100-4-5

Control Logic Noise Immunity:

Showering arc transients up to 1500V peak

Power Ride-Thru:

15 milliseconds at full load

Logic Control Ride-Thru:

0.5 seconds minimum, 2 seconds typical

Ground Fault Trip:

Phase-to-ground on drive output

Short Circuit Trip:

Phase-to-phase on drive output

Environment

(1)

(1) PowerFlex DC drives must be installed in a Pollution Degree 2 environment. See Pollution Degree Ratings According to EN 61800-5-1 on

page

42

for details.

Altitude:

1000 m (3300 ft) max. without derating.
De-rate output power by 1.2% for every 100 meters (328ft) above
1000 meters (3300ft).

Maximum Surrounding Air
Temperature IP20, NEMA/UL Type
Open:

0…50° C (32…122° F), typical.
De-rate 1.25% for every 1° C over 50° C (122° F), to 55° C (131° F).
Additional cooling is required for temps. above 55° C.

Storage Temp. (all const.):

–25…55° C (–13…131° F)

Atmosphere:

Important: Drive must not be installed in an area where the
ambient atmosphere contains volatile or corrosive gas, vapors or
dust. If the drive is not going to be installed for a period of time, it
must be stored in an area where it will not be exposed to a
corrosive atmosphere.

Relative Humidity:

Operating: 5…85% non-condensing
Storage: 5…95% non-condensing

Shock:

15G peak for 11ms duration (

±

1.0 ms)

Vibration:

0.152 mm (0.006 in.) displacement, 1G peak