Chapter 3

Programming and Parameters

APPLIC

AT

IONS

Win

der

Fu

nc

ti

on

s

1176 [Taper Enable]

Enables/Disables the Taper function.

Default:

Options:

0 =

0 =
1 =

“Disabled”

“Disabled”
“Enabled”

16-bit
Int

1177 [Initial Diameter]

Diameter that starts the taper tension reduction.

Default:

Min/Max:
Units:

0.10

0.00 / 32.00
m

Real

1178 [Final Diameter]

Diameter that ends the taper tension reduction.

Default:

Min/Max:
Units:

1.00

0.00 / 32.00
m

Real

1179 [Tension Reduct]

Taper tension reduction as a percentage of Par 1180 [Tension Ref].

Default:

Min/Max:
Units:

0.00

0.00 / 199.99
%

Real

1180

1180 [Tension Ref]

Tension reference.
Note: This parameter can be assigned to an analog input or output.

Default:

Min/Max:
Units:

0.00

0.00 / 199.99
%

Real

1181 [Tension Scale]

Scale factor of the torque current. This parameter is used when the value of the
maximum winding torque must be limited or when a closed loop control is used in
order to adjust the torque current value to the real tension on the material
measured by the load cell.

Default:

Min/Max:
Units:

100

0 / 200
%

16-bit
Int

1182 [Time AccDec Min]

The amount of time corresponding to the lower acceleration, decelera-
tion and fast deceleration time.

Default:

Min/Max:
Units:

9.00

0.15 / 300
s

Real

1183 [Int Acc Calc En]

Enables/Disables the calculation for coil acceleration.
“Enabled” = This function carries out the calculation of the angular acceleration

inside the drive. In this case it is necessary to set just the value of Par 1182
[Time AccDec Min].

“Disabled” = It is necessary to set Pars 1184 [Line Accel Pct], 1185 [Line Decel

Pct], 1186 [Line FastStp Pct] and 1182 [Time AccDec Min] and to supply the
corresponding status indication to the digital inputs.

Default:

Options:

1 =

0 =
1 =

“Enabled”

“Disabled”
“Enabled”

16-bit
Int

1182,
1184,
1185,
1186

1184 [Line Accel Pct]

Acceleration time as a percentage Par 1182 of [Time AccDec Min].

Default:

Min/Max:
Units:

100.00

0.00 / 100.00
%

Real

1182

1185 [Line Decel Pct]

Deceleration time as a percentage of Par 1182 [Time AccDec Min].

Default:

Min/Max:
Units:

100.00

0.00 / 100.00
%

Real

1182

1186 [Line FastStp Pct]

Fast deceleration time as a percentage of Par 1182 [Time AccDec Min].

Default:

Min/Max:
Units:

100.00

0.00 / 100.00
%

Real

1182

1188 [Accel Status]

Indicates the drive acceleration status.
“0” = Off - Drive not accelerating
“1” = “On” - Drive accelerating
Note: This parameter can be assigned to a digital output.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

1189 [Decel Status]

Indicates the drive deceleration status.
“0” = “Off” - Drive not decelerating
“1” = “On” - Drive decelerating
Note: This parameter can be assigned to a digital output.

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

1190 [Fast Stop Status]

Indicates the drive fast stop status.
“0” = “Off” - Drive is not fast stopping
“1” = “On” - Drive is fast stopping

Default:

Min/Max:

Read Only

0 / 1

16-bit
Int

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

A

A

A

A

A

A

A

A

A

A

A