Utility file, Param access lvl – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 163

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

163

Programming and Parameters

Chapter 3

Utility File

Fil

e

Gr

ou

p

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

UTILIT

Y

Referenc

e Con

fig

209

[Save HIM Ref]

Enables a feature to save the present reference value issued by the HIM to drive memory when a power loss occurs. The value is restored to the HIM at power
up.
Bit 0 - “At Pwr Down” 0 = Do not save, 1 = Save at power down

210

[Man Ref Preload]

Enables/disables a feature to automatically load the present “Auto” reference
value into the HIM when “Manual” is selected. Allows smooth speed transition
from “Auto” to “Manual.”

Default:

Options:

1 =

0 =
1 =

“Enabled”

“Disabled”
“Enabled”

16-bit
Int

249

[Save MOP Ref]

Enables/Disables the feature that saves the present MOP reference at power down or at stop.
Note: This parameter can be assigned to a digital input.
Bit 0 “At Pwr Down” - When set to “0” = Do not save, “1” = Save
Bit 1 “At Stop” - When set to “0” = Do not save, “1” = Save

1322 [Direction Mode]

Selects the method that will be used for changing direction.
“Unipolar” - Drive Logic determines the direction.
“Bipolar” - The sign of the reference determines the direction.
“Rev Disable” - Forward direction only (not changeable).

Default:

Options:

0 =

0 =
1 =
2 =

“Unipolar”

“Unipolar”
“Bipolar”
“Rev Disable”

16-bit
Int

1375 [MOP Select]

Selects the destination of the MOP signal.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =

“OFF”

”OFF”
“Speed Ref A”
“Speed Ref B”
“Trim Speed”
“TB Man Ref”

16-bit
Int

Dr

iv

e M

em

or

y

211

[Param Access Lvl]

Selects the parameter display level.
“Basic” = Reduced parameter set.
“Advanced” = Full parameter set.

Default:

Options:

0 =

0 =
1 =

“Basic”

“Basic”
“Advanced”

16-bit
Int

258

[Reset Defaults]

Setting this parameter to 1 “Factory” will load the default settings in the drive
firmware.

Default:

Options:

0 =

0 =
1 =

“Ready”

“Ready”
“Factory”

16-bit
Int

302

[Language]

Selects the operating language of the drive. Only two languages are available in
the drive at any given time, English and one of the following: French, German,
Italian, Portuguese, or Spanish. The drive ships with the default language options
of English and Spanish only. The additional language files can be downloaded at:

http://www.ab.com/support/abdrives/webupdate/powerflexdc.html#

Note: This parameter was added for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =

“Not Selected”

“Not Selected”
“English”
“French”
“Spanish”
“Italian”
“German”
“Reserved”
“Portuguese”

16-bit
Int

Options

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

At

P

w

r D

ow

n

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

At

S

to

p

At

P

w

r D

ow

n

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Advertising