Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 124

Advertising
background image

124

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

Chapter 3

Programming and Parameters

MO

TOR C

ONTROL

M

ot

or Da

ta

201

[Drive Type Sel]

Important:

This parameter is only applicable to non-regenerative (2-
quadrant) drives.

Allows non-regenerative drives to use an external 4-quadrant controller.
“On” = Ramp, Speed, Torque current references and Speed measurement

have the same behavior as a four quadrant drive.

Default:

Options:

0 =

0 =
1 =

“Off”

“Off”
“On”

16-bit
Int

280

[Nom Mtr Fld Amps]

Rated motor nameplate field current (I

dFN

). Leave set to the default value for

permanent magnet motor applications.

Default:

Min/Max:
Units:

Par 374 [Drv Fld Brdg Cur] x 0.33

0.00 / [Drv Fld Brdg Cur]
A

Real

374

[Drv Fld Brdg Cur]

Drive rated field bridge current (I

dFN

). The value in this parameter must be set

equal to the value chosen with DIP switch S14 on the control board (see

Table 15

on page

61

for DIP switch configuration). Leave set to the default

value for permanent magnet motor applications.

Default:

Min/Max:
Units:

1.00

0.50 / 80.00
A

Real

376

[MtrOvrld Type]

Allows selection of the type of motor overload calculation based on Par 179
[Motor Arm Amps].
StandardDuty = 150% load for 1 minute or 200% load for 3 seconds

before a motor overload condition is indicated.

HeavyDuty = 200% load for 1 minute before a motor overload condition

is indicated (250% for 30 sec). This selection requires that the drive be
oversized relative to the motor in order to be able to provide the necessary
current without faulting from a “Drive Overload” (F.64).

Note: This parameter was added for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =

“StandardDuty”

“StandardDuty”
“HeavyDuty”

16-bit
Int

179,
479,
1290

464

[SAR Volts Scale]

Scales the following parameters so that they show actual voltage values
rather than drive calculated values when in Standalone Regulator (SAR)
mode:

Notes: This parameter was added for firmware version 4.001. See Appendix H
PowerFlex DC Standalone Regulator Installation on page

349

for more

information.
Important: When the drive is not in SAR mode, this parameter is clamped to
the default value (1.0).

Default:

Min/Max:

1.0

0.5 / 10.0

Real

Fie

ld Co

nf

ig

91

[Fld Reg Kp]

Proportional gain (K

P

) of the flux regulator expressed as a percentage of Par

97 [Fld Reg Kp Base]. Leave set to the default value for permanent magnet
motor applications.

Default:

Min/Max:
Units:

2.00

0.00 / 100.00
%

Real

97

92

[Fld Reg Ki]

Integral gain (K

I

) of the flux regulator expressed as a percentage of Par 98 [Fld

Reg Ki Base]. Leave set to the default value for permanent magnet motor
applications.

Default:

Min/Max:
Units:

1.00

0.00 / 100.00
%

Real

98

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

ATTENTION: Failure to set this parameter to a value appropriate for the intended application could result in
equipment damage and/or personal injury.

A

175 [Motor Rated Volt]

495 [Arm Volt Kp Base]

233 [Output Voltage]

496 [Arm Volt Ki Base]

466 [AC Line Voltage]

1052 [Output Power]

481 [Undervolt Thresh]

1374 [Fault Voltage]