Programming and Parameters

Chapter 3

MO

TOR C

ONTROL

Au

tot

u

ne

1013

[Torque Const]

The Motor torque constant used to calculate inertia and friction
compensation. This value is determined during speed auto tuning. Torque
Const = EMF/Sb. It should be the same as Motor Rated Torque / Motor Full
Load Amps.

Default:

Min/Max:
Units:

Based on motor current rating

0.01 / 99.99
N•m/A

Real

1014

[Inertia]

Motor inertia value.
1 Kg•m

2

= 23.76 lb•ft

2

Default:

Min/Max:
Units:

Based on drive current rating (Par 179)

0.001 / 999.999
Kg•m

2

Real

1015

[Friction]

Motor friction value.
1 N•m = 0.738 lb•ft

Default:

Min/Max:
Units:

Based on drive current rating (Par 179)

0.000 / 99.990
N•m

Real

1027

[Spd Reg Autotune]

Starts the auto tuning procedure for the speed regulator. Setting this
parameter to 1 “On” and pressing “Start” on the HIM keypad initiates the
speed regulator auto tuning procedure. When the auto tuning procedure is
complete, this parameter automatically resets to 0 “Off”. This test should be
run with inertia connected to the motor (if present), but without process load
(i.e., material).
Speed Regulator Autotune assumes full field is applied. Verify Pars 280 [Nom
Mtr Fld Amps] and 467 [Max Fld Curr Pct] are set correctly. Tuning with less
than full field current will result in different gains because of the lower motor
torque values.
Note: Non-default values for Par 107 [Speed Zero Level] or Par 108 [Speed
Zero Delay] can interfere with successful Speed Loop autotuning.

Default:

Options:

0 =

0 =
1 =

“Off”

“Off”
“On”

16-bit
Int

280,
467

1029

[Speed Tune Dir]

Choice of the rotation direction of the motor shaft (rotation, as seen from the
motor shaft side) for the speed regulator auto tuning procedure.
“Forward” = Clockwise rotation
“Reverse” = Counter-clockwise rotation

Default:

Options:

1 =

1 =
2 =

“Forward”

“Forward”
“Reverse”

16-bit
Int

1030

[Spd Tune Inertia]

Motor inertia value identified during the speed regulator auto tuning
procedure.

Default:

Min/Max:
Units:

Read Only

0.001 / 999.990
Kg x m

2

Real

1031

[SpdTune Friction]

Motor friction value identified during the speed regulator auto tuning
procedure.

Default:

Min/Max:
Units:

Read Only

0.00 / 99.99
N•m

Real

1032

[Speed Tune Kp]

Proportional gain value of the speed regulator identified during the speed
regulator auto tuning procedure.

Default:

Min/Max:

Read Only

0.00 / 100.00

Real

1033

[Speed Tune Ki]

Integral gain value of the speed regulator identified during the speed
regulator auto tuning procedure.

Default:

Min/Max:

Read Only

0.00 / 100.00

Real

1048

[Autotune Cur Lim]

Value of the torque current limit applied during the speed regulator auto
tuning procedure.

Default:

Min/Max:
Units:

20

0 / Based on drive current rating
%

16-bit
Int

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 110

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

ATTENTION: The motor will rotate during the Speed Regulator tuning procedure. A hazard of personal injury exists
due to motor shaft rotation and/or machinery motion.

Advertising