Figure 19, Po w er fl ex d c drive, Figure 19 - power wiring with ac input contactor – Rockwell Automation 20P PowerFlex Digital DC Drive User Manual

Page 47

Advertising
background image

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

47

Installation and Wiring

Chapter 1

Figure 19 - Power Wiring with AC Input Contactor

M

C

D

Aux

Po

w

er

Fl

ex

D

C

Drive

36

(8)

34

(4)

(on I/O TB4)

19

(5)

(+2

4V on I/O TB2)

(N

.O

. R

el

ay)

M1 AC Contactor

Co

nt

ro

l

Bo

ar

d P/

S

AC Input

Voltage

115V

or

230V

(1)

V2

U2

F2

A1

A2

35

(8)

U

V

W

3 P

has

e

AC lin

e

L1

L2

L3

13

14

L1

L2

L3

A1

T1

T2

T3

A2

U1

V1

C1

D1

F1

FS2

(6)

FS2

(6)

FS1

(3)

FS1

(3)

FS1

(3)

FU1

FV1

FU

FU

Field Power Terminal Block

Control Power / Relay Outputs

Terminal Block

A1

A2

Armature Volt.

Fdbk. Term.

(7)

1A1

1A2

U3

V3

Fan Power Terminal Block

(9)

230V

FU

FU

Line Reactor

(2)

Isolation

Transformer

(2)

Lockable

Installation

Disconnect

SB

(1)

SA

(1)

These connections

must be taken from

the primary side of

the Isolation Transformer

or Line Reactor

(clean power).

AC Input

Voltage

PE

Safety Ground

AC Input

Voltage

460 VAC

Max. or

230 VAC

Min.

(10)

(1)

F

or frame B

and C

d

riv

es only,

a jum

per

is

requi

red

between

te

rmi

nals SA an

d SB

fo

r 115V AC

cont

rol input p

ower. See C

ontro

l Ci

rc

ui

t In

pu

t Po

w

er

o

n p

ag

e

65

fo

r m

ore

infor

m

ation.

(2

) An I

sola

tio

n

Transforme

r and

/or 3…

5% im

ped

anc

e Li

ne Rea

ctor

is

requ

ired

. If

the Iso

lati

on

Tr

ansf

orme

r pro

vi

des

the requ

ired

3…

5%

im

pe

da

nc

e,

a L

in

e Re

ac

to

r is

n

ot

req

uire

d.

Se

e AC

In

pu

t L

ine

Re

ac

tors a

nd AC

In

pu

t C

on

ta

ctor

s on

pa

ge

238

an

d I

sol

at

io

n

Tr

an

sf

or

me

rs

o

n p

ag

e

24

1

for

rec

omm

endations.

(3

) A

C

inp

ut f

uses f

or the

arma

tu

re co

nv

erte

r are

custom

er supp

lied

fo

r f

ra

m

e

A

and

B

driv

es a

nd a

re i

nternal

ly m

ou

nted

on

fram

e C

an

d D d

riv

es. S

ee Dri

ve

Po

wer Ci

rcui

t Pro

te

ctio

n o

n p

age

219

fo

r fuse re

co

m

m

endations.

(4)

Par 140 [Di

gital In8 Se

l] set to 31 “C

ontacto

r”

(5

) I

f u

si

ng

th

e +

24

V

int

erna

l p

ow

er

su

pp

ly,

te

rmi

nal

18

(2

4V

co

mmo

n)

mu

st

b

e ju

mpere

d t

o t

ermi

nal

35

(d

igi

tal

inp

ut

co

mmo

n).

(6)

Cu

sto

m

er

su

pp

lied

a

rm

atu

re

ou

tp

ut

fu

se

s a

re req

ui

re

d o

n

fo

ur q

uad

rant

a

nd

are

re

co

mmend

ed

o

n t

w

o

qua

dra

nt

Frame

A

an

d B

dri

ve

s.

See

D

riv

e P

ow

er

Cir

cuit

P

rot

ect

ion

on

pa

ge

21

9

for f

us

e recomme

ndat

io

ns

.

(7

) Op

tio

nal

arma

tu

re

vo

ltag

e f

ee

db

ack

se

nsi

ng

no

t re

qu

ired

wit

h A

C co

nt

act

or.

(8)

Par 1391 [C

ont

acto

rCo

ntrol]

= 1

“A

C

Cn

tctr” an

d Par 1392 [

Relay

Ou

t 1 Se

l] = 25 “C

ontactor

”.

Impor

tant

: T

er

m

in

al

35 an

d

36

a

re

on

th

e C

on

tro

l P

owe

r / Re

la

y

Ou

tputs Te

rm

ina

l b

lo

ck, NOT th

e I

/O

te

rm

in

al

b

loc

ks

. S

ee

Fi

gu

re

35

on

pa

ge

63

Fi

gu

re

37

on pa

ge

64

.

(9

) F

ra

m

e

C &

D dri

ves o

nly

req

uire

an

ex

te

rnal

po

wer sup

ply

fo

r the

hea

tsin

k cool

ing

fan. See

Fram

e C

Hea

tsin

k C

oolin

g F

ans P

ow

er Supp

ly Termi

nal

s on pa

ge

68

and

Fram

e D

Hea

tsi

nk C

oo

lin

g

Fan

Po

w

er Su

pp

ly T

ermin

als

o

n p

ag

e

69

fo

r mo

re

infor

m

ation.

(1

0)

Se

e Fi

eld

Co

nv

erte

r Conne

ctions

on

pa

ge

56

.

Advertising