Rockwell Automation Publication 20P-UM001I-EN-P - February 2013

159

Programming and Parameters

Chapter 3

APPL

IC

AT

IONS

Win

der Fun

ct

io

ns

1191 [InertiaCompCnst]

Displays the active compensation of the fixed section as a percentage of the drive
rated current.

Default:

Min/Max:
Units:

Read Only

0.00 / 200.00
%

Real

1192 [InertiaCompVar]

Displays the active compensation of the variable section as a percentage of the
drive rated current.

Default:

Min/Max:
Units:

Read Only

0.00 / 200.00
%

Real

1193 [Torq Current Pct]

Displays the amount of torque current required.
Note: This parameter can be assigned to an analog output.

Default:

Min/Max:
Units:

Read Only

0.00 / 200.00
%

Real

1194 [Act Ten Ref Pct]

Displays the percentage of tension reference less the Taper percentage set via Par
1179 [Tension Reduct]. If the Taper function is not enabled, it corresponds to the
value displayed in Par 1180 [Tension Ref].

Default:

Min/Max:
Units:

Read Only

0.00 / 199.99
%

Real

1179,
1180

1195 [Speed Match]

Coil “launching” phase command for automatic switching.
Note: This parameter can be assigned to a digital input or output.

Default:

Options:

0 =

0 =
1 =

“Off”

“Off”
“On”

16-bit
Int

1196 [Spd Match Acc]

Motor acceleration time during the launching phase.

Default:

Min/Max:
Units:

83.88

0.30 / 300.00
s

Real

1197 [Spd Match Dec]

Motor deceleration time. If the motor decelerates during the launching phase a
stop command is issued.

Default:

Min/Max:
Units:

83.88

0.30 / 300.00
s

Real

1198 [Offs Accel Time]

Ramp time for the initial phase when the machine is stopped. It refers to Par 45
[Max Ref Speed].

Default:

Min/Max:
Units:

83.88

0.30 / 300.00
s

Real

1199 [W Offset]

Speed reference offset for the initial phase of the winder/unwinder when the line
is stopped.

Default:

Min/Max:
Units:

0

0 / 1000
rpm

16-bit
Int

1200 [Spd Match Gain]

Speed reference gain during the launching phase. 100% corresponds to a
peripheral speed equal to the line speed.

Default:

Min/Max:
Units:

100

0 / 150
%

16-bit
Int

1201 [Winder Side]

Selection of the winding/unwinding side.
“0” = Up
“1” = Down
Note: This parameter can be assigned to a digital input.

Default:

Min/Max:

0

0 / 1

16-bit
Int

1202 [W Gain]

Sets the speed reference gain used to saturate the speed loop. This parameter is a
percentage of the increasing/decreasing value of the angular speed reference.

Default:

Min/Max:
Units:

0

0 / 100
%

16-bit
Int

1203 [Spd Match Compl]

Indicates a completed launching ramp. If this parameter is assigned to a
programmed digital output, it can be used to indicate that the coil can be changed.
“1” = Launching ramp completed
“0” = Launching ramp not completed

Default:

Min/Max:

Read Only

0 / 32767

16-bit
Int

1208 [Close Loop Comp]

Active compensation status (output of the PID regulator).

Default:

Min/Max:

Read Only

– / +32767

16-bit
Int

1209 [Torque Winder En]

Enables/disables the center winder function.

Default:

Options:

0 =

0 =
1 =

“Disabled”

“Disabled”
“Enabled”

16-bit
Int

Fil

e

Gr

oup

No

.