162

QC5200 Series User’s Guide

Assigning measurement tolerances

Bilateral or unilateral tolerances can be assigned to profile measurements. Bilateral tolerances can be equal

or unequal. Click the Tolerance button to display the tolerance zone dialog box.

Equal bilateral tolerances

Bilateral tolerance values will be centered around the edges of the nominal profile. For example, an equal

bilateral tolerance of 0.005 will be applied as ±0.0025.

Check the Bilateral box and enter

the desired tolerance value into the

Tolerance data field for equal bilat-

eral tolerances.

Unequal tolerances

Unequal bilateral or unilateral tol-

erance values are specified by the

user for In-material and Out-material tolerances. The example below shows a bore with different In-mate-

rial and Out-material tolerances.

Clear the Bilateral box and enter

the desired In-material and Out-

material tolerance values in the data

fields provided.

Tolerances can be applied to up to

5 different (Form) areas of the part

profile. To apply a tolerance to an

area, select the area using the mouse cursor in the Measure Profile window, then apply a tolerance as

shown above. Tolerance (Form) areas can be displayed and edited by clicking the Tools/Tolerance/Profile

menu item.

An equal bilateral tolerance of 0.005 is applied as ±0.0025

Unequal bilateral tolerances are applied as +0.003 and -0.001

Selected areas...

can be assigned different tolerances that are shown and edited in the

Advanced Profile Tolerance Results screen