327

1

0

Supervisor Setup

Configuring joystick and footswitch buttons

Use the Buttons screen in systems that include CNC functions to assign frequently used QC5200 system

functions to joystick and optional foot switch buttons. Using preassigned buttons saves the time normally

required to navigate menus to invoke frequently used functions.

Click the Tools/Options/Buttons menu item to dis-

play the Buttons screen.

Each of the joystick and foot switch buttons can be

assigned to 1 of 14 QC5200 system functions in

the Buttons screen. Thereafter, pressing the button

invokes the assigned function.

Level-based button functions

Many button functions are invoked only once when

the button is pressed. Others can be configured to

be momentary (level-based) or to toggle functions

on or off. Momentary functions are active only

while the button is pressed and held. Toggle func-

tions are activated when the button is pressed and

deactivated when the button is pressed again.

Button functions that are invoked

only once

Button functions that are invoked only once when

the button is pressed include:

• Measure: OK

• Measure: Enter pt

• Measure: Remove last

• Measure: Cancel

• View from probe

• Go to here

• Pause program

• Run program

NOTE

None of the eight button functions listed above can be configured as momentary (level-

based).

Joystick and Footswitch Setup