68

QC5200 Series User’s Guide

Construct the datum point from the intersection of the skew line and the left part vertical line.

You will be asked to confirm that your reference frame is complete. Click Yes. The program will include

the datum and record the part registration.

The reference frame will be shown in the Part

View window, and subsequent measurements will

be referred to the new datum.

Select the Skew Line and the

vertical line...

click the Zero Point toolbar button...

Click OK to complete the

Zero point construction

Confirm that the reference frame is complete...