3 elt meas - measuring parameters – Metrohm tiamo 2.3 Patch 1 (process analysis) User Manual

Page 1139

Advertising
background image

■■■■■■■■■■■■■■■■■■■■■■

5 Method

tiamo 2.3 Patch 1 (for Process Analysis)

■■■■■■■■

1123

automatic
If a temperature sensor is connected then the temperature will be
measured continuously. Otherwise the temperature entered manually
under Temperature on the Titration parameters tab will be used.
off
The temperature will not be measured. The temperature entered man-
ually under Temperature on the Titration parameters tab will be
used.

Stirrer

Stirrer

Selection of the stirrer.

Titrando, 867
Selection

1 | 2 | 3 | 4

Default value

1

855
Selection

1 | 2 | 3

Default value

1

Stirring rate

Setting the stirring rate. The algebraic sign of the stirring rate changes the
direction in which the stirring is done.

Range

-15 ... 15 (without 0)

Default value

8

5.6.5.9.3

ELT MEAS - Measuring parameters

Tab: Method

ELT MEAS Properties... Measuring parameters

Command name

Name of the command.

Input

25 characters

Temperature

Temperature

Measuring temperature which can be entered manually. If a temperature
sensor is connected and the Temperature measurement is set on the
General/Hardware tab under Sensor to automatic or continuous,
then the temperature will be measured continuously.

Range

-20.0 ... 150 °C

Default value

25.0 °C