Festo Контроллер позиционирования CPX-CMAX User Manual

Page 100

Advertising
background image

3. Drive functions

3−38

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

The axis zero point offset has a great influence on CMAX conĆ
troller optimisation. Even small values (a few mm) must be
specified as exactly as possible:

ć

The distance between the used stop (of the reference
point) and the cylinder end position (retracted piston rod)
is measured as the offset and entered as a negative value.

ć

When the piston rod is completely retracted (cylinder end
position) the value 0 must be entered as the offset.

Note
If the offset is imprecisely entered, the drive could end up
vibrating strongly depending on the setting of the involved
parameters.

·

Always carry out identification again after the offset has
been corrected.

Advertising