Festo Контроллер позиционирования CPX-CMAX User Manual

Page 159

Advertising
background image

4. Faults and diagnostics

4−23

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Fault group 4 ć system error A

CPX error group 104 (CPX−MMI: [System error A] )

continued

No.

Type

1)

Error handling

Cause/description

Message

44

Teaching not possible

2)

(continued)

Specified record number
impermissible when
teaching to BA set selecĆ
tion

·

Correct record
number.

Level: F1
Reset: R
Info: x

Parametrised control
mode of the selected reĆ
cord during teaching to
BA record selection not
permissible

·

Correct control mode,
correct record
number.

45

Faulty commissioning
operation or parameter

Invalid function number
when starting a commisĆ
sioning operation in
commissioning mode.

3)

·

Correct the function
number.

Level: F1
Reset: R
Info: x

At least one parameter
of the started commisĆ
sioning operation had an
invalid value.

3)

·

Check and correct
parameter 1 and
parameter 2.

Movement test was
started when a moveĆ
ment test has already
been successfully perĆ
formed.

·

First reset movement
test.

46

Start during active teach
command not permitted

Commissioning mode:
Starting a commissionĆ
ing function during
teaching is not
permissible.

·

Do not perform Start
during teaching, first
end teaching.

Level: F1
Reset: R
Info: x

47

Starting the tracking
mode requires MC

Starting the tracking
mode during an active
positioning task is imĆ
permissible.

·

End active positioning
task and wait for
Motion Compete
(SPOS.MC=1).

Level: F1
Reset: R
Info: x

1)

Level: fault level, see section 4.2.3; (can alternatively be parametrised as a warning or error)
Reset: behaviour upon reset, see section 4.2.4
Info:

ć = no info; x = additional info, see FCT or section 4.3.3

2)

For exact cause, see diagnostic memory.

3)

See I/O data in the description CMAX communication profile"

Advertising