4. Faults and diagnostics

4−39

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Information and details on the faults (PNU 202)

Info (bit 11 ... 08)

Details (bit 07... 00)

Value

Description

Value

Description

3

Cause of fault E44
(teaching not

1

Not specified.

(teaching not
possible)

2

In direct operating it is not possible to teach (no teach target).

possible)

3

Homing not carried out.

4

Commissioning: Unknown teach target specified in
parameter 1.

5

Record selection: Impermissible record number (0 or > 64)

6

Record selection: Impermissible control mode preset in the
selected record

7

Commissioning: Teaching lower software end
position >= upper software end position not permissible

8

Commissioning: Teaching upper software end
position <= lower software end position not permissible

9

Commissioning: Teaching is not permissible while a commisĆ
sioning operation is being carried out.

4

Record number

nn

In the event of a general fault in operating mode Record
select, the number of the record started last is entered.
Value range nn: 0 to 255

5

Commissioning
operation

nn

In the event of a general fault in commissioning mode,
the commissioning operation started last is entered.
Value range nn: 0 to 255