3. Drive functions

3−39

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

3.2.4

Homing run methods

The homing methods are oriented towards CANopen DS 402.

Homing methods

Hex

Dec

Description

23h

35

Current position

·

The current position is saved as the reference
point.

There is no movement, not even for checking
whether pressure is applied.

EFh

−17

Negative stop

·

Run at homing speed in negative direction to
stop. This position is saved as a reference
point.

EEh

−18

Positive stop

·

Run at reference speed in positive direction to
stop. This position is saved as a reference
point.

Tab. 3/14: Overview of homing methods