5. Parameter

5−101

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Start configuration

PNU

PNU: 1195

Index: 1 ... 5

Max index: 5

Class: Struct

Data type: int32

Values

See description of the respective index.

Default: 0

Minimum: −

Maximum: −

These are important configuration data at the time of adopting the serial numbers. The current conĆ
figuration may only be modified within certain limits after this point in time.
Index

Value

Setpoint
configuration

Unit

Tolerance

1

Cylinder length

PNU 1101

Length (index 2)

5.00 mm

2

Sensor length

PNU 1111

Length (index 2)

5.00 mm

3

Sampling time

ć

1 Ģsec

4

Mounting position

PNU 1140

Mounting angle (index 12)

5

Supply pressure

PNU 1141

Pressure (index 4)

1 bar

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Notes on PNU 1195:

The actual configuration is

ć

compatible: The actual configuration corresponds with
the setpoint configuration within the permissible limits.
Serial numbers may vary.

ć

identical: The actual configuration corresponds with the
identification configuration within the permissible limits.
The serial numbers are identical.

If the configuration is not identical, warning W08 (component
exchanged) is issued upon the first start. If it is not compatĆ
ible, error message E01 (configuration error) is issued. The
application data is used to check whether certain changes
are permissible without resetting the identification data.

Only automatically recognized configuration data can be
compared to the setpoint configuration.