5. Parameter

5−68

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Default value acceleration

PNU

PNU: 602

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Acceleration (index = 7)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.001 m/s

2

2.000

10

100.000

1

°/s

2

1.000

10

100.000

Imperial 0.01 ft/s

2

650

3

32.808

1

°/s

2

1.000

10

100.000

This value contains the acceleration preset by the user. It is used in all records with position control
where no individual acceleration is specified.
RPC−Bit = Bit 2 (=0000.0004h)

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.

Default value deceleration)

PNU

PNU: 603

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Acceleration (index = 7)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0,001 m/s

2

2.000

10

100.000

1

°/s

2

1000

10

100.000

Imperial 0.01 ft/s

2

650

3

32.808

1

°/s

2

1000

10

100.000

This value contains the deceleration preset by the user. It is used in all records with position control
where no individual deceleration is specified.
RPC−Bit = Bit 3 (= 0000.0008h)

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.