Festo Контроллер позиционирования CPX-CMAX User Manual

Page 116

Advertising
background image

3. Drive functions

3−54

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Typical errors and warnings during teaching

No.

Type

Cause

W35

Actual position is outĆ
side of the software
end position

The software end positions were passed during teaching.

E44

Teaching not possible

Teaching cannot be executed. For reasons, see Tab. 3/17.

E46

Start during teaching
is not allowed.

Commissioning mode: During CPOS.TEACH = 1, no commissioning
operation can be started. Reason: Both the teaching function as well
as the commissioning operation use parameter 1.

Causes for E44: Teaching not possible

Teaching is not possible in direct mode (no teach target).

Homing not executed

Commissioning: Unknown teach target specified in parameter 1

Record selection: Impermissible record number (0 or > 64)

Record selection: Impermissible control mode preset in the selected record

Commissioning: Teaching lower software end position >= upper software end position is not
permissible

Commissioning: Teaching upper software end position <= lower software end position is not
permissible

Commissioning: Teaching is not permissible while a commissioning operation is being executed.

Tab. 3/17: Causes for error E44 during teaching

The cause for E44 during teaching is shown in the diagnostic
memory in accordance with Tab. 3/17.

Advertising