3. Drive functions

3−21

Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH

Movement monitoring (SPOS.MOV)

The bit SPOS.MOV indicates that the drive is moving. For this,
CMAX checks whether the speed signal exceeds the internal
limit (4 mm/s).

The internal status Drive in motion" is additionally filtered
with the switch−off time to simplify the evaluation in a PLC
program.

1

Target setpoint value

2

Reference setpoint
value

3

Actual value

4

Speed

5

Speed tolerance

6

Motion Complete
(SPOS.MC)

7

Internal status
Drive in motion"

8

Axis is moving
(SPOS.MOV)

9

Switch−off time T

OFF

1

2

3

4

5

6

7

9

8

9 9

Fig. 3/5:

Movement monitoring

Overview of parameters involved

Parameters involved

Description

PNU

Speed tolerance (fixed: ±4 mm/s or 0.16 in/s)

ć

Switch−off time T

OFF

(fixed: 30 ms)

ć

Tab. 3/7: Parameters involved in movement monitoring