15 identification, Identification, Section 5.4.15 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 276

Advertising
background image

5. Parameter

5−88

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

5.4.15 Identification

Identification settings

PNU

PNU: 1170

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Without unit

Default: 0

Minimum: 0

Maximum: 1

The parameter allows you to make certain settings that concern identification.
= 0: Identification permits high accelerations
= 1: Only perform the static identification (low accelerations)

o

The parameter value cannot be changed.

ý

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

ý

After writing, controller recalculation is carried out.

Identification status

PNU

PNU: 1171

Index: 1

Max index: 1

Class: Var

Data type: bitarray

Values

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Write:

Current status according to the identification carried out last.
Bit 0 = 0: Identification has not yet been carried out.

= 1: Identification has been carried out at least once.

Bit 1 = 0: Results of the static identification are not available.

= 1: Static identification carried out successfully.

Bit 2 = 0: Results of the dynamic identification are not available.

= 1: Dynamic identification carried out successfully.

ý

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.