5. Parameter

5−64

Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH

Direct mode position tolerance

PNU

PNU: 545

Index: 1

Max index: 1

Class: Var

Data type: int32

Values

Unit: Position (index = 1)

Linear drive

Semi−rotary drive

Dimension

Default

Minimum

Maximum

Dimension Default

Minimum

Maximum

SI 0.01 mm

100

10

1.000

0,1

°

10

1

100

Imperial 0.001 in

40

4

394

0,1

°

10

1

100

Tolerance in position control direct mode.
Depending on PNU 521:02, the corresponding default value is used instead, if necessary.

o

The parameter value cannot be changed.

o

Writing permissible only in commissioning/parametrising mode with disabled controller.

o

This parameter can be written by FCT without higher−order controller.

o

After writing, controller recalculation is carried out.